We use cookies to ensure that we give you the best experience on our website and to constantly adjust our website to your needs. We also use cookies to provide you with helpful features and value added functionality. To use the website with full comfort, please accept to receive all cookies on our website.

Accept Decline

Heat pumps

Heat pumps use the free available environmental warmth to guarantee the heat supply of single, double, or multi-family houses. This is one of the most economical, effective and at the same time environmentally friendly ways to ensure the hot water and heating comfort.

Heat pumps gain natural energy from the ground, the ground water or the air and make significant savings in heating costs while doing so. They produce no emissions and operate efficiently even at low ambient temperatures. Heat pumps take up to 75 per cent of the required energy from the environment. Only 25 per cent of the energy has to be added in the form of electricity. This energy provides the power to operate the heat pump. Heat pumps are particularly suitable for use with underfloor heating and radiators with low surface temperatures. Due to technical limitations the efficiency of heat pumps falls sharply at temperatures above 67 °C.

The advantages of a heat pump system from Vaillant:

  • The utilisation of natural, inexhaustible energy sources
  • Emission-free
  • Efficient: up to 75 per cent of the energy comes from the environment, only 25 per cent must be added in the form of electricity
  • Can be used for cooling in summer
  • Simple high-value technology with low maintenance and a long service life

How a heat pump works

The technology of heat pump works on the reverse principle of the refrigerator. While a refrigerator transfers heat from inside to the outside, the heat pump extracts the heat from its environment and passes it on. The heat of the groundwater, the ground or the atmosphere is absorbed by a refrigerant and used to supply heat after compression.

Overall, the heat pump goes through a cycle of four steps: evaporation, compression, liquefaction and relaxation.

  1. In the first step the refrigerant absorbs the heat energy of the environment due to the low temperature of the refrigerant in the heat pump. In doing so, it changes to a gaseous state because of the low evaporation temperature of the refrigerant.
  2. The resulting vapour is compressed using a compressor. The molecules of the gas rub against each other more as a result of the increased pressure in a confined space. This produces higher temperatures which are used for the heating circuit.
  3. In the third step, the hot gas gives up its heat to the heating system. The refrigerant becomes liquid again.
  4. Finally, an expansion valve reduces the pressure generated in step 2, so that the refrigerant re-absorbs ambient heat and the process can start again.

The cooling function of heat pumps

Vaillant heat pumps may also be used to cool the house during the summer months. In case of brine/water systems, heat is extracted from the living space via the underfloor heating system and then discharged via the collector into the ground.

Depending on the intensity of the required cooling performance and the existing supply system, active or passive cooling will be suitable.

Active cooling

With the active reversal of the heating circuit the heat pump may be used as a cooling module in summer. The heat extracted from the heating system is then actively transferred to the heat source – e.g. the ground, by means of the compressor.

The former liquefier works as an evaporator in cooling. It transfers the room heat to the coolant. The gaseous coolant is then led into the condenser and from there to the heat exchanger which releases the heat extracted from the rooms to the ground.

Passive cooling

If during the summer months the room temperatures exceed the temperatures of the energy source, the heat pumps may as well operate as "natural cooling". It is quite easy to realise this function from the technical point of view.

With "natural cooling" the primary circuit pump is switched on while the condenser is not operated. The heat transfer medium, e.g. the brine, is transported to the heat exchanger. There, it gets into contact with the heating water which is at room temperature, it has been transported there by the heating circuit pumps. Temperatures of these 2 fluids are brought to the same level now. The cooled down heating water then circulates in the heating system extracting heat from the rooms.

Passive saves electric power - active is more efficient

Both methods, the active as well as the passive method, allow for the production of domestic hot water. Passive cooling is extremely energy saving due to the low power consumption only required for the circulators. However, there are some cut-backs regarding performance and efficiency in case of the passive method. Especially at the end of the summer the ground has normally stored a large quantity of heat. As a result, the cooling output of this exchanger medium will decrease.

A cooling function is available for some of our heat pumps.

The right heating system

There is no standard solution when searching for the right heating system. But it is not that difficult to find the system that fits your needs. Talk with your Vaillant heating specialist. They can assist you in planning your new heating installation.